How out LabView .VI reads incoming voltages and tells the motors to adjust
|
|
|
|
|
|
|
|
|
|
Receives digital numbers on X Voltmeter
|
|
Is the number greater than .00001 and greater than -.00001
| NO
|
Is the number less than .00001 and greater than -.00001?
|
| |
| |
|
YES
|
|
NO
|
YES
|
|
|
|
|
Divide the number by 2.5, multiply by -100, and then input that number into the relative distance input on the ThorLabs .VI
|
|
Divide the number by 2.5, multiply by -100, and then input that number into the relative distance input on the ThorLabs .VI
|
|
Do nothing
|
| |
| |
|
|
|
|
|
|
|
|
|
|
|
Receives digital numbers on Y Voltmeter
|
|
Is the number greater than .00001 and greater than -.00001
| NO
|
Is the number less than .00001 and greater than -.00001?
|
| |
|
|
|
YES
|
|
NO
|
YES
|
|
|
|
|
Divide the number by 2.5, multiply by 100, and then input that number into the relative distance input on the ThorLabs .VI
|
|
Divide the number by 2.5, multiply by -100, and then input that number into the relative distance input on the ThorLabs .VI
|
|
Do nothing
|
| |
|
|
|
|
|
|
|
|
|
|
|
Repeat
|
|
Send both X and Y voltages to XY graph generator
|
| |
| |
|
|
|
|
|
|
|
|
|
|
| |
| |
| |
| |
|
|
|
|
|
|
|
|
|
|
| |
| |
| |
| |
|
|
|
|
|
|
|
|
|